Instruments & Equipment

Instruments & Equipment

Analytical Balance

Send Message

Overview:

The balance is mainly used for precise weighing based on the principle of electromagnetic force balance or strain gauge sensing technology. When an object is placed on the weighing platform of the balance, the sensor detects the minute changes caused by the object and converts them into digital signals via an electronic system, which are eventually displayed on the screen.

Features of the FB-A Series

  • Electromagnetic force sensor, stable weighing, four-level shock resistance.
  • Intelligent automatic internal calibration, convenient and fast.
  • Large space anti-wind cover; cast aluminum housing, anti-static interference, corrosion-resistant, more accurate weighing.
  • LCD liquid crystal display, clear reading, suitable for different scenarios.
  • Full range tare; counting; unit conversion (g/mg/ct/oz).
  • Percentage weighing; Sensitivity and speed are adjustable.
  • Overload alarm; fault alarm; level indicator.

Features of the FB-C Series

  • LCD liquid crystal display, clear reading, suitable for different scenarios.
  • AC/DC dual use.
  • Full range tare; counting; unit conversion (g/mg/ct/oz).
  • The minimum initiating weighing quantity is adjustable.
  • Overload alarm; level indicator.

Features of the FB-D Series

  • Large space anti-wind cover; cast aluminum housing, anti-static interference, corrosion-resistant, more accurate weighing.
  • LED digital display, clear reading, suitable for different scenarios.
  • Full range tare; counting.
  • Overload alarm; level indicator.

Technical Data:

Cat.no FB-A-01 FB-A-02 FB-A-03 FB-A-04 FB-A-05 FB-A-06 FB-A-01L FB-A-02L FB-A-03L FB-A-04L
Analytical Balance (Thousandth digit) Measuring Range 200g 300g 500g 600g 1000g 1200g 200g 300g 500g 600g
Accuracy 0.001g
Minimum Weighing Capacity 0.004g
Repeatability ±0.002g
Linearity ±0.003g
Stabilization Time ≤3s
Pan Size Ф80mm Ф100mm Ф80mm
Dimensions (D*W*H) 350*205*365mm
Windproof Cover Size 240*190*265mm
Interface RS232(Standard Configuration)   USB(Optional Configuration)
Operating Temperature 15-35℃
Calibration Method External Calibration Internal Calibration
Calibration Weights 200g 500g 200g
Package Size Interior Box:415*285*430mm     Exterior Box:475*315*485mm
Gross Weight 10kg 11kg

 

Cat.no FB-C-01 FB-C-02 FB-C-03 FB-D-01 FB-D-02 FB-D-03
Analytical Balance (Thousandth digit) Measuring Range 110g 210g 310g 110g 210g 310g
Accuracy 0.001g 0.001g
Minimum Weighing Capacity 0.001g-0.004g 0.004g
Repeatability ±0.002g ±0.002g
Linearity ±0.003g ±0.003g
Stabilization Time ≤3s ≤3s
Pan Size Ф90mm Ф90mm
Dimensions (D*W*H) 270*200*270mm 350*205*365mm
Windproof Cover Size 175*180*205mm 240*190*265mm
Interface N/A RS232(Standard Configuration)
Calibration Method External Calibration External Calibration
Calibration Weights 100g 200g 100g 200g
Package Size Interior Box:360*265*350mm   Interior Box:415*285*430mm  
Exterior Box:730*560*380mm Exterior Box:475*315*485mm
Gross Weight 4kg 7.5kg

Environmental Conditions

  • The workshop should be maintained clean and dry.
  • The balance should be placed on a stable and fixed workbench (it is suggested to be placed on a marble platform).
  • The workbench should be distant from doors and windows to minimize the impact of airflows resulting from their opening.
  • The workbench should be positioned in an area with minimal vibration interference.
  • The balance should be placed in a location that avoids direct sunlight and is distant from heat sources that may cause temperature variations.
  • Please refrain from connecting to large machines or equipment with interference to avoid disturbances from other devices.
  • Dry environments are prone to static electricity; corresponding measures should be adopted to prevent the impact of static electricity on weighing.
  • The balance should be kept away from magnetic or objects and equipment capable of generating magnetic fields.
  • The balance must not be utilized in areas with explosive hazards.
  • The balance should not be employed for extended periods in environments with high humidity or excessive dust.
  • When the balance is transferred from a colder environment to a warmer one, moisture in the air can condense within the balance, thereby influencing the accuracy and reliability of weighing. To eliminate the effect of moisture condensation, the balance can be placed at room temperature without power for 2 hours before use.

Precautions

  • Prior to using the balance, it should be horizontally positioned. Adjust the level using the adjustment screws at the bottom of the balance until the bubble in the level gauge is centered within the circle. To ensure accurate weighing, it is essential to ensure adequate preheating of the balance (a preheating time of one hour is recommended).
  • Do not use sharp objects (such as pencils or ballpoint pens) to press the keys; only use fingers for key pressing.
  • Take care to prevent objects from falling from heights onto the weighing pan to avoid damaging the weighing mechanism.
  • Do not expose the balance to high humidity or dusty environments for prolonged periods.
  • After using the balance, it is advisable to cover it with a cover to prevent dust infiltration.
  • When weighing powders and fine particles, ensure the use of appropriate containers to prevent dust and particles from entering the weighing sensor beneath the weighing pan.
  • When calibrating with weights, please wear gloves and refrain from handling the weights directly with hands.
  • Maintain the balance clean and dry.
  • Do not employ corrosive cleaning agents (such as solvents); a non-linting soft cloth dampened with water and a little neutral detergent (soap) can be used for cleaning.
  • Before cleaning, unplug the power supply. During cleaning, be cautious to prevent water from entering the balance.
  • After cleaning, carefully dry the balance with a dry non-linting soft cloth.
  • Regularly calibrate the balance with standard weights to ensure its precision.